Programmable Valve Actuator (PVA)

Features and Benefits:

  • Quarter-Turn Actuator
  • Up to 10,000 in-lbs Torque and 12” Valve
  • High-Performance Embedded PAC/PLC Inside:
  • Function Block Programming
  • PVA Specific Function Blocks
  • Detailed Fault Detection and Diagnostics
  • Versatile I/O (Up to 4 Analog Inputs, 4 Digital Inputs, and/or 2 Digital Outputs)
  • Embedded Inlet / Outlet Pressure Sensors with Flow Calculation Capability
  • Up to Two 10/100 Ethernet Interfaces with Industry
  • Standard Communications and Data Encryption
  • Local / Remote Operator Panel
  • 115VAC (1-phase) or 440VAC (3-phase)
  • Adjustable Mechanical End Stops
  • Software Adjustable Torque and Position Limits
  • Fast Closure: <10s for up to 4,000 in-lbs.
  • Motor Options Include MIL-M-17059, MIL-M-17060, and MIL-STD-2037 (Sealed System Insulation)
  • Many Safety Related Features
  • Sealed Enclosure for Harsh Environment
  • -40°C to +65°C (-40°F to +149°F) Operating Range
  • DOD-V-24657*, MIL-STD-461E*, MIL-S-901D*, MIL-STD-167-1*, MIL-STD-1399

*Qualified with a 3rd party valve. All new actuator/valve pair applications may need to be re-qualified.


What is the Programmable Valve Actuator (PVA)?

The Fairmount Automation PVA Series is a family of Programmable Valve Actuators designed in accordance with MIL-Spec DOD-V-24657 (SH) with advanced electronic features to meet today’s demanding requirements of naval applications. The PVA has an embedded PAC/PLC Processor, I/O Interface, and Ethernet network interface that enables the development of distributed autonomous valve control systems.

Programmable Valve Actuator

The PVA is equipped with a wide array of I/O capabilities. The PVA has the capability of interfacing to four (4) analog inputs, four (4) digital inputs, two (2) digital relay outputs, and 2 integrated pressure sensors. The actual I/O capability is defined on an application by application basis.

Packaging

The PVA’s corrosion resistant construction makes the controller extremely rugged—it is specifically designed for operation in environments susceptible to extreme temperature, humidity, pollution, corrosion, shock, and/or vibration. The PVA’s small form factor makes it a very good choice for dense packed military applications.

Local Operator Interface Panel

Local Operating Panel

  • The PVA is designed to include a local operator interface panel (LOIP). The LOIP provides the user with the ability to:
  • Place the valve into local manual control or remote automatic.
  • Manually open, stop, and close the valve
  • Monitoring the Open and Closed Status of the Valve.
  • Wireless download the PVA application program the PVA via the sealable IR Port.

The LOIP and PVA can be configured to be remotely mounted from each other for ease of operator access to control and observe valve operation.

Function Block based Application Programming

Design Pad G4 Graphical Programming Environment

The PVA is configured with the Design Pad G4 graphical programming environment. Design Pad technology makes setting up, debugging, and fine-tuning your control scheme quick and easy. It also allows the device to be very versatile — virtually every feature from the local operator interface displays to the back-panel I/O and in-between can have their attributes customized to fit your needs.

The PVA also supports various industrial networking protocols via the integrated Ethernet communication ports. Supported protocols include TCP/IP, UDP, Ethernet/IP, Modbus/TCP, and the FA FANDA Protocol (which utilizes FIPS certified encryption libraries).

Diagnostics

  • The PVA contains a variety of on-board diagnostic capabilities including:
  • Open/Close Torque Exceeded
  • Failed to Open/Close
  • Motor Over-Temperature
  • Motor Over-Current
  • Motor Maximum Motion Profile Time Exceeded
  • Motor Stall Detected
  • Input Power Phase Loss
  • Input Power Phase Rotation Out Of Order
  • Submergence Keypad Pressure Sensor Active
  • Valve Pressure Sensor(s) Out Of Range
  • Analog Input Faults (Under/Over Current, RTD Open/Short, etc.)
  • Position Sensor Out of Range
  • Internal Communications Failure

VALVE INTERFACE

Model Number PVA15 PVA45 PVA100
Weight 49 lbs (22 kg) 53 lbs (24 kg) 53 lbs. (24 kg)
Output Torque 1,500 in-lbs. 4,500 in-lbs. 10,000 in-lbs.
Stroke Time 10-60 sec 10-60 sec 20-60 sec

 

ENVIRONMENTAL CHARACTERISTICS*

Operating Ambient Temperature Range

-40°C to 65°C

Storage/Transport Ambient Temperature Range

-40°C to 85°C

High Impact Shock

MIL-STD-901D, Grade A

Actuator

DOD-V-24657

Mechanical Vibration

MIL-STD-167B

Electro-Magnetic Interference

MIL-STD-461E, E3, EMP

Housing Protection

Fully Sealed, Silicon Bronze, 

Submersible to 50ft,

Corrosion Resistant

Power Interface

MIL-STD-1399

*Qualified with a 3rd party valve. All new actuator/valve pair applications may need to be re-qualified.

 

GENERAL ELECTRICAL CHARACTERISTICS

Power

110V Single Phase or 440VAC Three Phase, 200W

Cable Connections

Circular Connectors

 

ANALOG INPUTS

Quantity / Resolution

4 Channels / 16 Bits Minimum

Sampling Rate

10Hz typical (varies on Mode and number of channels used)

Current Input Ranges Supported

0-20mA, 4-20mA

Current Input Accuracy

+/-40uA at 25°C, +/-100uA Over Temperature

Standard Voltage Input Ranges Supported

0-20V, 0-10V, 0-5V, 1-5V, 0-2.5V

Standard Voltage Input Range Accuracy

+/-36mV at 25°C, +/-86mV Over Temperature

Low Voltage Input Ranges Supported

0-1V, 0-500mV, 0-250mV, 0-100mV

Low Voltage Input Range Accuracy

+/-2mV at 25°C, +/-5mV Over Temperature

Resistance Input Range Supported

0-2400Ω

Resistance Input Range Accuracy

+/-2.4 or +/-0.4% of Reading (whichever is smaller) Over Temperature

RTD Support

3 Wire, 100Ω Platinum (European or American curve), 120Ω Nickel, or Custom

RTD Accuracy

+/- 1°C Over Temperature

 

DIGITAL INPUTS

Quantity

4

Maximum Allowable Continuous Input Voltage

200 VDC or 140 VAC RMS

Maximum Allowable Voltage Spike

1000V peak 1.2µS x 50µS pulse per MIL-STD-1399 Section 300

Logic High Voltage Range

5-200 VDC or 24-130 VAC RMS 55-500 Hz

Minimum Input Duration for Logic High Detection

4 ms

Logic Low Voltage Range

0-1 VDC or 0-0.5 VAC RMS 55-500 Hz

Minimum Input Duration For Logic Low Detection

56 ms

Minimum Input Current Required (AC and DC inputs)

5mA RMS

 

DIGITAL OUTPUTS

Quantity / Type

2 Form “A” Solid State

Voltage Rating

110 VAC, 250 VDC Resistive (Inductive Loads Require External Clamp)

Maximum Allowed Continuous Current

1 Amps

Electrical Isolation:
Any Output to Control Circuitry or Chassis Ground

1500 VDC for 1 minute

 

PRESSURE SENSOR

Quantity

1 Inlet and 1 Outlet

Pressure Range

0 to 200psi or 0 to 500psi

 

NETWORK

Copper Connections

Up to Two Ports with Embedded Switch, 10/100Mbps,
Twisted Pair Wires, AutoMDI and 1500 VDC Isolation

Protocols

EtherNet/IP Client and/or Server,
Modbus TCP/IP Client or Server,
FANDA Server with FIPS Encryption

 

OPERATOR INTERFACE

Open / Close Indication

Two User-Programmable High-brightness LEDs

Push Buttons

Open. Close, and Stop Button

with Submergence Lock-Out

Hand Wheel

4” (102 mm)

Auto / Manual Switch

Two-Position Detent with Two

User-Programmable Position Indication LEDs

IR Wireless Interface

115KBPS SIR With Blocking Cap

Status Indication

Three-Color LED

 