AC Power Supply Module Type 1 (ACP-1)
Features and Benefits
- 25W 110 VAC Power Supply
- Fully Sealed Enclosure (NEMA 4X, 6, 13 Protection)
- -40°C to +65°C (-40°F to +149°F) Operating Range
- MIL-S-901D Grade A for High Impact Shock
- MIL-STD-167B for Vibration
- MIL-STD-461E for Electro-Magnetic Interference (EMI)
- MIL-STD-1399 (See Specifications) Section 300 Voltage Spike
- Supports Hot Swapping
- Multiple Modules Can be Paralleled to Provide Load Sharing, Uninterrupted Power During Hot Swap, and/or Redundant Power Sources
- Modules will function with both Chameleon and Chameleon+ products
The Chameleon 25W AC Power Module (ACP-1) filters, pre-regulates, and distributes electrical power to other Chameleon modules connected to it. Multiple power modules attached to each other and fed from different power sources can provide seamless redundancy, reducing susceptibility to power outages, or providing load sharing to increase the available power. Power modules on the same node are always online—if one should lose input power, another will instantaneously compensate and deliver uninterrupted power to all loads.
ACP-1 units are hot swappable: should the need arise to replace one, simply swap the front panel (with attached power board) and the unit is back online—there is no need to shut off the power. When the module is swapped out, all storage capacitors are automatically discharged to prevent shocking hazard. The module also features input circuit fusing and automatic output over-current shutdown.
As with all Chameleon modules, the ACP-1 offers unequaled ruggedness. It is specifically designed for sustained operation in severe environments, including those characterized by extreme shock, vibration, electro-magnetic interference, temperature, and/or humidity. Its fully-sealed enclosure (sealing end-caps not pictured) ensures long-lasting operation in the grimiest settings. In fact, Chameleon modules can operate fully submerged.
ENVIRONMENTAL CHARACTERISTICS | |
Operating Ambient Temperature Range | -40°C to 65°C |
Storage/Transport Ambient Temperature Range | -40°C to 85°C |
High Impact Shock | MIL-S-901D, Grade A |
Mechanical Vibration | MIL-STD-167B, 0-50Hz |
Electro-Magnetic Interference | MIL-STD-461E |
Facial/Housing Protection | NEMA 1,2,4,4X,5,6,12,12K,13 |
ELECTRICAL CHARACTERISTICS | |
Input Voltage Range | 75-123VAC |
Input Frequency | 40 to 400Hz |
Input Spike Tolerance | 1000V (2Ω source impedance) |
Interface Standard | Subset of MIL-STD-1399. See KB Article here for details. |
Output Power | 25 Watts |
Output Isolation (Primary to Secondary) | 1500 VAC |
Maximum inrush current (115 VAC at Full Load) | 12 A RMS for 5 ms |
Maximum steady state input power (115 VAC at Full Load) | 35 Watts |
Power Factor (115 VAC at Full Load) | 0.63 |
Turn-on time at 90 VAC | 40 ms |
Hold-up time at 90 VAC | 30 ms |
Input Fuse | 1A rating, I2T=2.01 A2-sec |
Supported Cable Diameters | Two glands 0.24”-0.47”; two glands 0.16”-0.31” |
Supported Wire Gauges | 16-28 AWG |
OPERATOR INTERFACE | |
Status Readouts | Power ON LED Indicator |
PHYSICAL CHARACTERISTICS | |
Weight | 1.5 lbs |
Front Panel Dimensions | 2.5” W x 6” L |
Enclosure Height | 3″ H |
The following part numbers can be used when ordering the AC Power Supply Module Type 1 (ACP-1).
Fairmount Part Number |
Description |
01012-001 | ACP-1 with Gray Enclosure |
01012-301 | ACP-1 with Black Enclosure (without Stuffing Tubes) |
11015-200 | ACP-1 Active Board and Gray Cover |
11015-250 | ACP-1 Active Board and Black Cover |
01014-001 | ACP-1 Half-Size Gray Enclosure with Wiring Hub Assembly |
01014-301 | ACP-1 Half-Size Black Enclosure and Wiring Hub Assembly (without Stuffing Tubes) |
11016-100 | ACP-1 Wiring Hub Assembly |
- Analog Input Module
- Multi-Loop Control
- Discrete I/O Modules
- Network Modules
- Expansion Cards
- User Configurable Modules
- Power Supply Modules
- Accessories
- Ordering Guide